SX
120
SX-RELAYS
HIGH SENSITIVITY RELA Y
WITH GUARANTEED LOW
LEVEL SWITCHING
CAPACITY
7.4
.291
15.0
.591 8.2
.323
mm inch
7.4
.291
15.0
.591 Max. 10.0
.394
FEATURES
1. High contact reliability over a long
life has been made possible for low
level loads.
Using a low le vel load (1 mV 10
µ
A to 10 V
10 mA) 10
7
operations were achieved with
a static contact resistance of Max. 100
m
Ω
(voltage drop of 20 mV, 1 mA, 1 kHz)
and a dynamic contact resistance of Max.
1
Ω
(Measurement delay 10 ms, voltage
drop of 20 mV, 1 mA, 1 kHz).
2. High sensitibity of 50 mW
By using the highly efficient polar magnet-
ic circuit "seesaw balance armature
mechanism", a rated pow er consumption
of 50 mW (f or single side stable type) has
been achieved.
3. Low thermal electromotive force
Reducing the heat from the coil enables a
thermal electromotive force of 3
µ
V or
less.
SPECIFICATIONS
Contact
Notes:
**
1
This value can change due to the s witching frequency , environmental conditions,
and desired reliability lev el, therefore it is recommended to chec k this with the ac-
tual load.
**
2
For single side stable only.
Characteristics
Remarks:
* Specifications will vary with foreign standards certification ratings.
*
1
By nominal switching capacity: No. of operations: 10
7
*
2
Measurement at same location as "Initial breakdown voltage" section.
*
3
Detection current: 10mA.
*
4
Nominal voltage applied to the coil, excluding contact bounce time.
*
5
By resistive method, nominal v oltage applied to the coil; contact carrying current:
10mA.
*
6
Half-wave pulse of sine wave: 6 ms; detection time: 10
µ
s.
*
7
Half-wave pulse of sine wave: 6 ms.
*
8
Detection time: 10
µ
s.
*
9
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
Arrangement 2 Form C
Static contact resistance (During initial and
electric life tests)*
1
(By voltage drop of 20 mV 1 mA [1kHz]) Max. 100 m
Ω
Dynamic contact resistance (During initial and
electric life tests)*
1
(By voltage drop of 20 mV 1 mA[1 kHz], Mea-
surement delay 10 ms after applying nominal
coil voltage)
Max. 1
Ω
Contact material Gold-clad silver alloy
Rating
Nominal switching capacity
(resistive load) 10 mA 10 VDC
Max. switching power 0.1 W
Max. switching voltage 10 VDC
Max. switching current 10 mA DC
Min. switching capacity**
1
10
µ
A 1 mVDC
Nominal
operating
power
Single side stable 50mW (1.5 to 12 V DC)
70mW (24 V DC)
1 coil latching 35mW (1.5 to 12 V DC)
50mW (24 V DC)
2 coil latching 70mW (1.5 to 12 V DC)
150mW (24 V DC)
Thermal electromotive force, max.
(at nominal voltage applied to the coil**
2
)3
µ
V
Expected
life (min.
operations)
Mechanical (at 750 cpm) 5
×
10
7
Electrical (at 750 cpm)
(10 mA 10 V DC resistive load) 10
7
Initial insulation resistance*
2
Min. 10,000M
Ω
(at 500V DC)
Initial
breakdown
voltage*
3
Between open contacts 750 Vrms for 1min.
Between contact sets 1,000 Vrms for 1min.
Between contact and coil 1,800 Vrms for 1min.
Operate time [Set time]*
4
(at 20
°
C) Max. 5 ms (Approx. 3 ms)
[Max. 5 ms (Approx. 3 ms)]
Release time (without diode)
[Reset time]*
4
(at 20
°
C) Max. 5 ms (Approx. 1.5 ms)
[Max. 5 ms (Approx. 3 ms)]
Temperature rise*
5
(at 20
°
C) Max. 50
°
C
Shock resistance Functional*
6
Min. 750 m/s
2
{75G]
Destructive*
7
Min. 1,000 m/s
2
{100G]
Vibration resistance Functional*
8
10 to 55 Hz at double
amplitude of 3.3 mm
Destructive 10 to 55 Hz at double
amplitude of 5 mm
Conditions for operation,
transport and storage*
9
(Not freezing and con-
densing at low tempera-
ture)
Ambient
temperature –40
°
C to 70
°
C
–40
°
F to 158
°
F
Humidity 5 to 85% R.H.
Unit weight Approx. 2 g .071 oz
TYPICAL APPLICATIONS
This relay will be used for the small load
for measuring instruments or others
where a stable contact resistance is
required.