SX (ASX)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Static contact resistance
(During initial and electric life tests)
Max. 100 mΩ (By voltage drop of 20 mV 1 mA [1kHz])
(By nominal switching capacity: No. of operations: 107)
Dynamic contact resistance
(During initial and electric life tests)
Max. 1 Ω (By voltage drop of 20 mV 1 mA [1 kHz], Measurement delay 10 ms after applying
nominal coil voltage) (By nominal switching capacity: No. of operations: 107)
Contact material Stationary contact: AgPd+Au clad Movable contact: AgPd
Rating
Nominal switching capacity 10 mA 10 V DC (resistive load)
Max. switching power 0.1 W (resistive load)
Max. switching voltage 10 V DC
Max. switching current 10 mA DC
Min. switching capacity (Reference value)*110 µA 1 mV DC
Nominal operating
power
Single side stable 50mW (1.5 to 12 V DC), 70mW (24 V DC)
1 coil latching 35mW (1.5 to 12 V DC), 50mW (24 V DC)
2 coil latching 70mW (1.5 to 12 V DC), 150mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 10,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160µs) (FCC Part 68)
Between contacts and coil 2,500 V (2×10µs) (Telcordia)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current:
10mA.)
Operate time [Set time] (at 20°C 68°F)Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20°C 68°F)Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 5 × 107 (at 750 cpm)
Electrical Min. 107 (10 mA 10 V DC resistive load) (at 750 cpm)
Thermal
electromotive force Max. 3µV (at nominal voltage applied to the coil)
Conditions Conditions for operation, transport and storage*2Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 750 cpm
Unit weight Approx. 2 g .071 oz
1. Switching capacity range 2-(1). Change in dynamic contact resistance
(10 mA 10 V DC resistive load)
Tested sample: ASX20012, 10 pcs.
Operating speed: 750 cpm
Measured condition: 10 ms after applying nominal coil
voltage, using voltage drop of 20 mV, 1 mA, 1 kHz.
2-(2). Change in dynamic contact resistance
(10 µA 1 mV DC resistive load)
Tested sample: ASX20012, 10 pcs.
Operating speed: 750 cpm
Measured condition: 10 ms after applying nominal coil
voltage, using voltage drop of 20 mV, 1 mA, 1 kHz.
10mA
10µA
1mV 10V
Contact voltage
Contact current
1,0000
Min.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Max.
No. of operations, × 104
Contact resistance, Ω
2,0001,0000
Min.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Max.
No. of operations, × 104
Contact resistance, Ω
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.