www.recom-power.com REV.: 1/2018 ECO-1
Features
Unregulated
Converters
High efficiency uo to 84% full load
Low deviation (10% - 100% load)
1kVDC and 2kVDC isolation option
UL60950-1 and EN/IEC60950-1 certified
-40°C to +100°C operating temperature range
1W SIP7 package
RB/E
Description
The RB/E series is an unregulated DC/DC converter in standard SIP7 package style. This series has been
designed to offer exceptionally high efficiency at low loads, an extended operating temperature range
and low deviation (10% to 100%). Uses include applications with restricted energy budget and industrial
applications where a high efficiency level is required.
DC/DC Converter
1 Watt
SIP7
Single Output
E358085
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
EN60950-1 certified
IEC60950-1 certified
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1) Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RB-3.305S/E (3,4) 3.3 5 200 83 2200
RB-0505S/E (3,4) 5 5 200 84 2200
RB-1205S/E (3,4) 12 5 200 84 2200
RB-2405S/E (3,4) 24 5 200 81 2200
Model Numbering
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/H“ for 2kVDC isolation
or add suffix „/HP“ for 2kVDC isolation and continuous short circuit protection
Ordering Examples:
RB-1205S/E: 12VDC Input Voltage, 5VDC Output Voltage, Single Output
RB-3.305S/EP: 3.3VDC Input Voltage, 5VDC Output Voltage, Single Output with continuous short circuit protection
RB-0505S/EH: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolation
RB-0505S/EHP: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolation and continuous short circuit protection
nom. Input Voltage
Output Voltage
RB- __ 05S/E
Protection (3)
Isolation Option (4)
Single
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
www.recom-power.com REV.: 1/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/E
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter type
Input Voltage Range ±10%
Start-uo time 250ms
Minimum Load (5) 0%
Internal Operating Frequency 20kHz 90kHz
Output Ripple and Noise 20MHz BW 50mVp-p 100mVp-p
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RB-xx05S/E
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
3.305
0505
1205
2405
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% max.
Load Regulation 10% to 100% load 12.0% typ.
continued on next page
Tolerance Envelope
+10%
+5%
Vnom
+5%
-2%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
www.recom-power.com REV.: 1/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/E
Series
Deviation vs. Load
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.305
0505
1205
2405
RB-xx05S/E
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP) without suffix
With suffix “/P”
1 second
continuous
Isolation Voltage (6) I/P to O/P
without suffix tested for 1 second
rated for 1 minute
1kVDC
500VAC
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVDC
Isolation Resistance 10G
min.
Isolation Capacitance 75pF max.
Insulation Grade basic
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range full load @ free air convection (see graph) -40°C to + 100°C
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C
+100°C
3459 x 103 hours
756 x 103 hours
continued on next page
www.recom-power.com REV.: 1/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/E
Series
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ free air convection)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
1602031 IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety E358085-A4-UL UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
non-conductive black plastic (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH) 19.6 x 6.0 x 10.2mm
Weight 2.2g typ.
continued on next page
www.recom-power.com REV.: 1/2018 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/E
Series
Pinning information
Pin # Single
1 +Vin
2 -Vin
4 NC
5 -Vout
6 +Vout
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
1 2 64 5 1 2 64 5
0.50
1.27 10.2
0.51+0.10/-0.05
6.0
1.00 Ø +0.15/-0
19.6
5x2.54= 12.702.00 2.54
2.54
4.10
0.25
±0.05
Marking
Bottom View
Top View
embossed logo
Dimension Drawing (mm)
Recommended Footprint Details
NC = no internal connection
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity tube 25pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.