GN (AGN)
3
ds_61007_en_gn: 280114D
3) High sensitivity single side stable type
*Pulse drive (JIS C 5442-1996)
2. Specifications
Notes:
*1
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Nominal coil
voltage Set voltage
(at 20C 68F)Reset voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)Nominal operating
power Max. applied voltage
(at 20C 68F)
1.5V DC
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
66.7mA 22.5
100mW 150%V of
nominal voltage
3V DC 33.3mA 90
4.5V DC 22.2mA 202.5
6V DC 16.7mA 360
9V DC 11.1mA 810
12V DC 8.3mA 1,440
24V DC 5.0mA 4,800120mW 120%V of
nominal voltage
Characteristics Item Specifications
Contact Arrangement 2 Form C
Initial contact resistance, max. Max. 100 m (By voltage drop 6 V DC 1A)
Contact material Stationary contact: AgPd+Au clad Movable contact: AgPd
Rating
Nominal switching capacity 1 A 30 V DC, 0.3 A 125 V AC (resistive load)
Max. switching power 30 W (DC), 37.5 V A (AC) (resistive load)
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 1 A
Min. switching capacity (Reference value)*110A 10 mV DC
Nominal operating
power
Single side stable 140mW (1.5 to 12 V DC), 230mW (24 V DC)
High sensitivity single side
stable type 100mW (1.5 to 12 V DC), 120mW (24 V DC)
1 coil latching
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,500 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial) Between open contacts 1,500 V (10160s) (FCC Part 68)
Between contacts and coil 2,500 V (210s) (Telcordia)
Temperature rise (at 20C 68F)Max. 50C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20C 68F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 5 107 (at 180 times/min.)
Electrical Min. 105 (1 A 30 V DC resistive), 105 (0.3 A 125 V AC resistive) (at 20 times/min.)
Conditions Conditions for operation, transport and storage*2
Ambient temperature:
(Single side stable, 1 coil latching type) –40C to +85C –40F to +185F
(High sensitivity single side stable type) –40C to +70C –40F to +158F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 1 g .035 oz
1. Max. switching capacity 2. Life curve 3. Mechanical life
Tested sample: AGN2004H, 15 pcs.;
Operating speed: 180 times/min
.
30 100
Contact voltage, V
1.0
0.3
DC resistive load
AC resistive load
Switching current, A
Switching current, A
No. of operations, × 104
0.2 0.4 0.6 0.8 1.0 1.2
100
50
30
40
20
10
0
DC 30V resistive load
AC 125V
resistive load
4
3.5
3
2.5
2
1.5
1
0.5
100
Max.
Min.
30 50
0
Max.
Min.
Pick-up voltage
Drop-out voltage
No. of operations, ×104
Voltage, V